advanced search
advanced search

Classified HKG842387

S&A chiller CW-5200 for Close water Cooled lab Press Plate

S&A chiller CW-5200 for Close water Cooled lab Press Plate

583$
Hong Kong
December 19, 2019
HKG842387
S&A chiller CW-5200 for Close water Cooled lab Press Plate
S&A CW-5200 water chiller is suitable to cool Close water Cooled lab Press Plate. Its cooling capacity up to 1.4KW and the thermoelectric control in ±0.3℃ precision and temperature control range in 5-35℃. It is popular for its 2 temperature control modes as constant temperature and intelligent temperature control.
CW-5200 water chiller parameter:
Model CW-5200AG CW-5200BG CW-5200DG CW-5200TG CW-5200AH CW-5200AI CW-5200BI CW-5200DI
Voltage 220V 220V 110V 220V 220V 220V 220V 110V
Frequency 50Hz 60Hz 60Hz 50/60Hz 50Hz 50Hz 60Hz 60Hz
Current 2.4~3.1A 2.6~3.3A 4.5~6.5A 2.4~3.3A 2.4~3.1A 2.4~3.1A 2.6~3.3A 4.5~6.5A
Compressor power 0.52KW 0.5KW 0.68KW 0.49/0.57KW 0.52KW 0.52KW 0.5KW 0.68KW
0.71HP 0.68HP 0.93HP 0.66/0.77HP 0.71HP 0.71HP 0.68HP 0.93HP
Refrigeration capacity 5084Btu/h 4982Btu/h 5186Btu/h 4825/5797Btu/h 5084Btu/h 5084Btu/h 4982Btu/h 5186Btu/h
1.49KW 1.46KW 1.56KW 1.41/1.70KW 1.49KW 1.49KW 1.46KW 1.56KW
1281Kcal/h 1256Kcal/h 1307Kcal/h 1219/1465Kcal/h 1281Kcal/h 1281Kcal/h 1256Kcal/h 1307Kcal/h
Refrigerant R-22 / R-134a / R-410a
Refrigerant charge 360g 380g 350g 360/380g 360g 360g 380g 350g
Precision ±0.3℃
Reducer Capillary
Protection Overcurrent protection for compressor, flow alarm, over temperature alarm
Pump power 0.03KW 0.05KW 0.1KW
Tank capacity 6L
Inlet and outlet External Φ10mm brass connector Φ10mm speedy connector
Max. lift 10 M 12M 25M
Max. flow 10 L/min 13L/min 16 L/min
N.W 26 Kgs
G.W 29 Kgs
Dimension 58 X 29 X 47 cm (L X W X H)
Package dimension 70 X 43 X 58 cm (L X W X H)
Note: other electric sources can be customized; heating and higher temperature control precision functions are optiona .
CONTACT S&A
TEL:+86-20-89301885, FAX:+86-20-84309967
SKYPE: teyuchiller
Email:marketing@teyuchiller.com